EasyManuals Logo

Precor SPINNER CHRONO POWER User Manual

Precor SPINNER CHRONO POWER
197 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #126 background imageLoading...
Page #126 background image
2.
Reconnect the Strain Gauge (J1) cable connector, then the Data COMM (J3) cable
connector and last the Generator (J5) ,cable connector. Do not cut the Mylar moisture
barrier to connect the Strain Gauge (J1) cable connector.
CAUTION:Do not cut the Mylar moisture barrier to either remove or install the
strain gauge cable connector. Cutting the barrier will allow sweat and other liquids
to damage the LPCA board.
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
Page 118
5 Replacement Procedures
LPCA board Replacement

Table of Contents

Other manuals for Precor SPINNER CHRONO POWER

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Precor SPINNER CHRONO POWER and is the answer not in the manual?

Precor SPINNER CHRONO POWER Specifications

General IconGeneral
BrandPrecor
ModelSPINNER CHRONO POWER
CategoryExercise Bike
LanguageEnglish

Related product manuals