73
Trouble code chart LPG
Check when operating on petrol and LPG that there is good lambda signal
movement.
Check when operating on petrol and LPG that there is good lambda signal
movement.
Lambda to long to lean during open
loop.
Check when operating on petrol and LPG that there is good lambda signal
movement.
Check if the ECT sensor (blue) in the reducer is connector is connected to
ground.
Check if the ECT sensor (blue) in the reducer has a power connection.
Check the ground connection of the Pressure/temperature sensor in the filter
unit.
Check the power connection of the Pressure/temperature sensor in the filter
unit.
Based on a pressure drop in the system, this can be caused by an empty LPG
tank, incorrect solenoid valve, polluted filter or incorrectly adjusted pressure.
Activate the LPG computer with the diagnostic program, using the F11 function
key.
LPG computer circuit board to hot, replace the VSI computer in a cooler area.
Check board voltage / alternator output and condition of the battery.
210-220-230-240-250-260-270-280
Injector current to high, check for short circuiting
211-221-231-241-251-261-271-281
Injector current to low, check for bad connections.
Adjusted pressure on idle out of range
Adjust the idle pressure to the value shown by parameter “ Idle Level “
Programm error during flahing the
memory
Check parameter settings, contact Prins Autogassystemen.
Check the ground connection of the Pressure/temperature sensor in the filter
unit.
Check the power connection of the Pressure/temperature sensor in the filter
unit.
Check the coolant temperature (T-ect) and the evaporator for leakage of the
first stage.
unexpected parameter change
Contact Prins Autogassystemen.
Check the water connections / circuit.
Gas leakage, system pressure is less then
1.25 bar after 4 hours when the engine is
not running
Check the system for gas leakage.
System switches to LPG but engine
stalls immediately.
LPG tank empty ?
Lock-off valves open ?
No injection timing on LPG ( 0 Msec.)
Check the injection module.
The LPG system switches constantly
between LPG and Petrol
- Check coolant system for air.
- T-ect sensor in the evaporator malfunction.
Engine hesitates on high revs, and not
running on all cylinders. Engine runs
good on idle.
Check for kinked or jammed LPG hoses (between VSI injector and couplings).
Check for blocked inlet couplings.
Switch LED’s don’t lit up
Check the main fuse of the VSI system
Check ignition+ (VSI wire 13)
Fault codes when turning the ignition
off ( key out the ignition )
Caused by different switch off times between ignition+ and injector power.
Connect VSI wire 13 to the petrol injector feed instead of ignition+.
The orange LED on the switch flashes
Activate the LPG computer with the diagnostic program, using the F11 function
key.
The LPG system switches to LPG but
engine stalls immediately
Not running on all cylinders on lpg
Check parameter 10, number of cylinders.
No injection times on lpg
Check the connections of the injection module.
Injection time “falls” to 0 mSec on
LPG
Check the injection module.
Check engine while running on LPG,
injector circuit malfunction, no lambda
control (limb home)
Not starting / running on petrol
Check the connections of the injection module.