110 PRODIGIT
5.10.1.8. Press START/STOP test key.
5.10.1.9. The UUT’s output voltage drop-out lower than the threshold voltage (V-th
Setting), and the OCP trip point is between I_Hi and I_Lo limitation, then
Middle 5 digits LCD display will shows "PASS", otherwise shows "FAIL".
5.10.2 Remote control OCP
EX
REMOTE
Set Remote
TCONFIG OCP
Set OCP test
OCP:START 3
Set start load current 3A
OCP:STEP 1
Set step load current 1A
OCP:STOP 5
Set stop load current 5A
VTH 0.6
Set OCP VTH 0.6V
IL 0
Set current low limit 0A
IH 5
Set current high limit 5A
NGENABLE ON
Set NG Enable ON
START
Start OCP testing
TESTING?
Ask Testing? 1Testing0Testing End
NG?
Ask PASS/FAIL?0PASS1FAIL
OCP?
Ask OCP current value
STOP
Stop OCP testing