EasyManuals Logo
Home>Prodigit>Power Supply>3350F Series

Prodigit 3350F Series User Manual

Prodigit 3350F Series
133 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #131 background imageLoading...
Page #131 background image
122 PRODIGIT
Appendix D 3350F Mainframe Auto. Sequ function provide
EDIT, ENTER, EXIT, TEST and STORE 5 keys operation.
Edit mode
1. Set mode, Range, current level  Load Setting and Load ON
2. Press STORE key to store the load setting in memory bank
3. Repeat 1~2, for the sequence load setting.
4. Press EDIT key of 3350F mainframe.
5. Press 1~9 number key program number.
6. Press BANK up/down key to select memory bank.
7. Press STATE up/down key to select memory state.
8. Press ENTER to next step.
9. Repeat 6~8 to edit Step of sequence
10. Press STORE to confirm the step
11. LCD shows “REP.” to setting repeat count.
12. Press up/down key to set repeat count of sequence loop.
13. Press STORE to confirm the sequence edit.
Test mode
1. Press TEST key of 3350F mainframe,
2. Press 1~9 number to select sequence number
3. Press ENTER to execution the sequence
4. The LCD shows “PASS” or “FAIL” after testing.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Prodigit 3350F Series and is the answer not in the manual?

Prodigit 3350F Series Specifications

General IconGeneral
BrandProdigit
Model3350F Series
CategoryPower Supply
LanguageEnglish