3350F Series Operation Manual 5
CR Mode:
At constant resistance mode, The 3350F Series Electronic Load will sink a current linearly
proportional to the load input voltage in accordance with the programmed resistance setting
(see Fig 1-8).
I
V
LOAD
CURRENT
INPUT VOLTAGE
RESISTANCE
SETTING
Fig 1-8 Constant Resistance mode
CV Mode:
At constant voltage mode, the 3350F Series Electronic Load will attempt to sink enough
current until the load input voltage is equaled to the programmed value (see Fig 1-9).
I
V
LOAD
CURRENT
INPUT VOLTAGE
VOLTAGE
SETTING
Fig 1-9 Constant Voltage mode