44 PRODIGIT
ISTAR: setting the start current point, The LCD display shows OCPon left 5
digit LCD display, Middle 5 digit LCD displayISTAR,right 5 digit LCD display
Setting value, the unit is "A".
The setting range is 0.00A to the full scale of the CC mode specification. The setting
Is by rotating the setting knob.
ISTEP: setting the increment step current point, The LCD display shows OCPon
left 5 digit LCD display, Middle 5 digit LCD displayISTEP,right 5 digit LCD
Display setting value, the unit is "A".
The setting range is 0.01A to the full scale of the CC mode specification. The setting
Is by rotating the setting knob.