Operating
Stroke rate In “manual”, “contact” and “batch” operating modes:
The stroke rate can be altered in the “stroke rate” display.
Feed rate In “manual” operating mode
The feed rate can be altered in the “feed rate” display.
Factor The factor is the number of strokes activated by an external pulse or a press of the P key (in
“batch” mode only).
In “contact” and “batch” operating modes:
You can alter the factor from the “remaining strokes” display.
The gamma/ L returns to the original continuous display a few seconds after the factor has been
reset.
Batch size In “batch” operating mode:
The batch size can by changed from the “batch size/remaining litres” display.
The gamma/ L returns to the original continuous display a few seconds after the batch size has
been reset.
Priming The “priming” function is activated by pressing both arrow keys at the same time.
Cancel error Error messages are cancelled by pressing the P key briefly.
Settings
mode
P
P
P
i
STOP
START
Continuous
display
2 s
Stopp/start pump
Change directly alterable values
= Security lock (CODE 1)
= Security lock (CODE 2)
Prime
Start batch (in "batch" operating mode only)
Cancel error
Check adjustable values
2
2
1
1
9.2 Remote control
It is possible to control the gamma/ L remotely via a signal cable (see section 6.3 and section 7
and appendix documentation).