Communication Protocol CubiScan 25 Command Set
CubiScan 25 Service Manual 62
5 6 Location Identifier Alpha
000000-ZZZZZ
Z
11 1 Comma Alpha (,) 2Ch
12 1 Length Identifier Alpha (L) 4C
13 5 Length Numeric
00.00 - 99.99
1
18 1 Comma Alpha (,) 2Ch
19 1 Width Identifier Alpha (W) 57h
20 5 Width Numeric
00.00 - 99.99
1
25 1 Comma Alpha (,) 2Ch
26 1 Height Identifier Alpha (H) 48h
27 5 Height Numeric
00.00 - 99.99
1
32 1 Comma Alpha (,) 2Ch
33 2 Dimension Unit Alpha (in/cm) 45h or 4Dh
35 1 Weight Identifier Alpha (K) 4Bh
36 6 Weight Numeric
00.000 -
99.999
2
42 1 Comma Alpha (,) 2Ch
43 1 Dim. Wgt. Identifier Alpha (D) 44h
44 6 Dim. Weight Numeric
000.00-999.99
1
50 1 Comma Alpha (,) 2Ch
51 2 Wgt./Dim.Wgt Unit Alpha (lb/kg)
53 1 Factor Identifier Alpha (F) 46h
54 4 Factor Numeric 0000-9999
58 1 Comma Alpha (,) 2Ch
59 1 Domestic/Int'l. Unit Alpha (D/I) 44h or 49h
60 1 End of Text Control (ETX) 03h
61 1 Carriage Return Control (CR) 0Dh
62 1 Line Feed Control (LF) 0Ah
Negative Acknowledge Format
1 1 Start of Text Control (STX) 02h
2 1 Measure Command Alpha (M) 4Dh
31Neg. Acknowledge Alpha (N) 4Eh
41
CubiScan/Host
Originated
Alpha (C/H) 43h or 48h
5 1 Measure/Zero Error Alpha (M/Z)
43h or 4Dh
or 5Ah
61End of Text Control(ETX) 03h
Pos Len Description Type Range ASCII