Communication Protocol CubiScan 25 Command Set
CubiScan 25 Service Manual 66
Reset System
This command causes the CubiScan 25 to reboot.
41End of Text Control(ETX) 03h
5 1 Carriage Return Control (CR) 0Dh
61Line Feed Control(LF) 0Ah
Negative Acknowledge Format
1 1 Start of Text Control (STX) 02h
2 1 Model Command Alpha (!) 21h
31Neg. Acknowledge Alpha (N) 4Eh
41End of Text Control(ETX) 03h
5 1 Carriage Return Control (CR) 0Dh
61Line Feed Control(LF) 0Ah
Pos Len Description Type Range ASCII
Command Format
1 1 Start of Text Control (STX) 02h
21Reset Command Alpha (x) 78h
31End of Text Control(ETX) 03h
4 1 Carriage Return Control (CR) 0Dh
51Line Feed Control(LF) 0Ah
Acknowledge Format
1 1 Start of Text Control (STX) 02h
21Reset Command Alpha (x) 78h
3 1 Acknowledge Alpha (A) 41h
41End of Text Control(ETX) 03h
5 1 Carriage Return Control (CR) 0Dh
61Line Feed Control(LF) 0Ah
Negative Acknowledge Format
1 1 Start of Text Control (STX) 02h
21Reset Command Alpha (x) 78h
31Neg. Acknowledge Alpha (N) 4Eh
41End of Text Control(ETX) 03h
5 1 Carriage Return Control (CR) 0Dh
61Line Feed Control(LF) 0Ah
Pos Len Description Type Range ASCII