• Type: Opons are custom or calculated. Custom sensors are dened by the hardware. Calculated sensors are
a sensors whose value is calculated using other sensors values. See below for more informaon on calculated
sensors.
• ID: This number indicates what type of sensor it is. It contains two parts. The rst part is the ID number
which denes the sensor type. The second part is the instance number for the hardware. If mulple sensors
of the same type are congures, the instance numbers must be unique.
• Unit: The unit for the sensor. This unit is used when the sensor value is displayed on the screen or read
aloud.
• Precision: Species the number of digits aer the decimal point when the sensor value is displayed on the
screen. The number is truncated based on this seng.
• Rao: Species the rao value to mulply with the sensor value as needed by some sensors.
• Oset: Species the oset value to add to the sensor value.
• Auto Oset: When selected, the rst received value is used as oset. You can use the Reset telemetry opon
to reset the oset on already congured sensors.
• Posive: When selected, the value of the sensor will be displayed only when it is a posive number. Displays
zero when the sensor value becomes a negave number.
• Filter: When selected, the sensor value becomes a rolling average of the last 5 received values.
• Logs: When selected, the value of this sensor will be saved in the log le. SD Card logging is congured in
Special Funcons or Global Funcons.
Calculated sensors contain the addional conguraon opons:
• Formula: Type of calculaon to use. Opons include:
o Add: Add the values of up to 4 designated sensors.
o Average: Calculates the average value of up to four designated sensors.
o Minimum: Find the minimum value of up to 4 designated sensors.
o Maximum: Find the maximum value of up to 4 designated sensors.
o Mulply: Mulplies the value of 2 sensors.
o Totalize: Calculate the cumulave value of one sensor.
o Cell: This is the formula for FrSKY Lipo baery sensor. It displays cell voltage specied by the number
in "Cell index" eld. If you specify "Lowest" in "Cell index" eld, the voltage of the cell with the
lowest is displayed. If you specify "Highest" in "Cell index" eld, the voltage of the cell with the
highest is displayed. If you specify "Delta" in "Cell index" eld, the voltage dierence between lowest
and highest cell is displayed
o Consumpon: Calculates the power consumpon (mAh) by cumulavely add the values of current
sensor.
o Distance: Calculates the distance between the receiver and the radio using GPS sensor and almeter
values.
• Source 1, 2, 3, 4: The sensors that will provide the argument values that are used in the formula dened
above.
• Persistent: When selected the sensor values will be saved when switching between models or powering
down the radio.