7. Telemetry
Telemetry is data received from the model to the radio from various sensors. These sensors may be included
in the radio receiver or ight controller or may be separate sensors, such as GPS, variometer, or
magnetometer. The received telemetry data can be displayed by EdgeTX in widgets, congured in alarms or
audio call-outs.
The Telemetry screen is where you congure these sensors to use in EdgeTX. Below are the following
conguraon opons:
7.1. Sensors
Sensors poron of the Telemetry screen
All previously congured sensors are listed here. The list is collapsible by clicking on the arrow icon to the
right side of the Sensors label. Sensors that have not received data since the model was loaded or the
telemetry values were reset display --- for the values. The asterisk * to the le of the sensor value will ash
when the sensor has received a data update. A solid asterisk* indicates that the sensors that are receiving
regular updates. Sensors that are no longer receiving regular updates will not be marked with the asterisk*.
See Common Telemetry Sensors for a list of commonly used sensors in EdgeTX.
The following opons are listed under the sensor list.
Discover New: When selected, it will look for new sensors on the model and automacally congure them. If
the sensor list is collapsed when a new sensor is discovered, the newly found sensor will be visible on the
sensor list (old sensors will remain collapsed/hidden).
Add New: When selected, it will create a new blank sensor for that must be congured manually.
Delete All: This opon will delete all previously congured sensors.
No inst. (ignore instances): This opon prevents mulple sensors from reporng the same telemetry data.
If no sensors are listed in the sensors secon, you may need to select Discover New to detect the sensors.
Addionally, not all RF protocols transmit telemetry data.
If you long-press the [Enter] buon for a specic sensor, the following opons will be displayed:
Edit: Allows you to edit the sensor's conguraon opons.
Copy: Creates a copy of that sensor.
Delete: Deletes that sensor.
See the Sensor Conguraon page for a detailed descripon of all the conguraon opons for seng up or
eding sensors.