Home
Raisecom
Marine Radio
iTN8600-I
Raisecom iTN8600-I User Manual
4
of 1
of 1 rating
71 pages
Give review
Manual
Specs
To Next Page
To Next Page
To Previous Page
To Previous Page
Loading...
Raisecom
iTN8600
-I (A) Product Description
5
Appendix
Raisecom Proprietar
y and Confidential
Copyright © Raisecom Tech
nology Co., Ltd.
34
Model
Tx
wavele
ngth
(nm)
Rx
wavelengt
h (nm)
Tx
optical
power
(dBm)
Overl
oad
(dBm)
Extinc
tion
ratio
(dB)
Rx
sensitivit
y (dBm)
Mo
de
Transmi
ssion
distance
(km)
USFP+-
192/SS13-I
1330
1260
–
1280
-4.5 to 1
> 1
> 4
<
-14.4
SM
20
USFP+-
192/SS22-I
1270
1320
–
1350
-1.5 to 5
>
-7
> 6
<
-19
SM
40
USFP+-
192/SS23-I
1330
1260
–
1280
-1.5 to 5
>
-7
> 6
<
-19
SM
40
5.1.2 DSFP+
10 Gbit/s (LC/PC
, dual-fiber bid
irectional, 40 km)
Ta
bl
e
5-
2
P
a
r
a
m
ete
r
s
of
D
SF
P+
m
od
ul
e
(
10
Gb
it
/
s
,
L
C/
PC
, dual
-
f
i
b
e
r
b
i
dir
ect
i
o
n
al
,
4
0
km
)
Model
Tx
wavele
ngth
(nm)
Rx
wavelength
(nm)
Chan
nel ID
Tx optical
power
(dBm)
Overloa
d (dBm)
Extincti
on ratio
(dB)
Rx
sensitivity
(dBm)
DSFP+-192/S/21
1560.61
1260
–
16
00
C21
-1.0 to 4.0
> 1
> 6
<
-15
DSFP+-192/S/2
2
1559.79
1260
–
16
00
C22
-1.0 to 4.0
> 1
> 6
<
-15
DSFP+-192/S/23
1558.98
1260
–
16
00
C23
-1.0 to 4.0
> 1
> 6
<
-15
DSFP+-192/S/2
4
1558.17
1260
–
16
00
C24
-1.0 to 4.0
> 1
> 6
<
-15
DSFP+-192/S/25
1557.36
1260
–
16
00
C25
-1.0 to 4.0
> 1
> 6
<
-15
DSFP+-192/S/2
6
1556.55
1260
–
16
00
C26
-1.0 to 4.0
> 1
> 6
<
-15
DSFP+-192/S/27
1555.75
1260
–
16
00
C27
-1.0 to 4.0
> 1
> 6
<
-15
DSFP+-192/S/2
8
1554.94
1260
–
16
00
C28
-1.0 to 4.0
> 1
> 6
<
-15
DSFP+-192/S/29
1554.13
1260
–
16
00
C29
-1.0 to 4.0
> 1
> 6
<
-15
DSFP+-192/S/
30
1553.33
1260
–
16
00
C30
-1.0 to 4.0
> 1
> 6
<
-15
DSFP+-192/S/31
1552.52
1260
–
16
00
C31
-1.0 to 4.0
> 1
> 6
<
-15
DSFP+-192/S/3
2
1551.72
1260
–
16
00
C32
-1.0 to 4.0
> 1
> 6
<
-15
DSFP+-192/S/33
1550.92
1260
–
16
00
C33
-1.0 to 4.0
> 1
> 6
<
-15
DSFP+-192/S/3
4
1550.12
1260
–
16
00
C34
-1.0 to 4.0
> 1
> 6
<
-15
DSFP+-192/S/35
1549.32
1260
–
16
00
C35
-1.0 to 4.0
> 1
> 6
<
-15
43
45
Table of Contents
Default Chapter
5
Table of Contents
5
1 Overview
11
Introduction
11
Networking Application
12
Figure 1-1 Front Appearance of the Itn8600-I-XT4D-AC
12
Figure 1-2 Front Appearance of the Itn8600-I-XT4D-DC
12
Figure 1-3 Appearance of the Itn8600-I-XT4D-AC and Itn8600-I-XT4D-DC
12
Figure 1-4 Typical Point-To-Point Application
14
Figure 1-5 Typical Point-To-Point WDM Application
15
Ordering Information
16
Device
16
Figure 1-6 Typical Ring Network Application
16
Table 1-1 Ordering Information about Device
16
Table 1-2 Client-Side Service Modes
17
Purchased Parts
18
Table 1-3 Ordering Information about Purchased Parts
18
Table 1-4 Ordering Information about Purchased Cables
19
Table 1-5 Comparison Table for Services, Quantity, Panel Interfaces, and Optical Modules
20
2 System Structure
22
Hardware Structure
22
Figure 2-1 Hardware Structure
22
Software Structure
23
Figure 2-2 Software Structure
23
3 Cards and Parts
24
Itn8600-I-XT4D
24
Version
24
Appearance
24
Table 3-1 Version of the Itn8600-I-XT4D
24
Functions
25
Figure 3-1 Appearance of the Itn8600-I-XT4D
25
Table 3-2 Functions of Itn8600-I
25
Interfaces
27
Table 3-3 Interfaces on the Itn8600-I
27
Leds
28
DC Power Supply RPD1304-48S12
28
Version
28
Appearance
28
Table 3-4 Leds on the Itn8600-I
28
Table 3-5 Version of the DC Power Supply
28
Functions
29
Interface
29
Led
29
Figure 3-2 Panel of the DC Power Supply
29
Table 3-6 Functions of the DC Power Supply
29
Table 3-7 Interface on the DC Power Supply
29
Table 3-8 LED on the DC Power Supply
29
Technical Specifications
30
Cable
30
AC Power Supply RPA1171-220S12
30
Version
30
Appearance
30
Table 3-9 Technical Specifications of the RPD2153-48D483V3
30
Table 3-10 DC Power Cable
30
Table 3-11 Version of the AC Power Supply
30
Functions
31
Interface
31
Led
31
Figure 3-3 Panel of the AC Power Supply
31
Table 3-12 Functions
31
Table 3-13 Interface on the AC Power Supply
31
Table 3-14 LED on the AC Power Supply
31
Technical Specifications
32
Cable
32
Fan FANS383
32
Version
32
Appearance
32
Table 3-15 Technical Specifications of the AC Power Supply RPA1171-220S12
32
Table 3-16 AC Power Cable
32
Table 3-17 Version of the Fan
32
Functions
33
Default Configurations
33
Figure 3-4 Panel of the Fan
33
Table 3-18 Functions of the Fan
33
Table 3-19 Default Configurations of the Itn8600-I-XT4D
33
4 Technical Specifications
34
Overall Specifications
34
Table 4-1 Overall Specifications
34
Laser Safety Class
35
Reliability Specifications
35
Table 4-2 Reliability Indexes
35
EMC Specifications
36
Security Standards
36
Environmental Requirements
36
Storage Environment
36
Table 4-3 Requirements for Climatic Environment for Storage
36
Table 4-4 Concentration Requirements for the Mechanical Active Substance in Storage
37
Table 4-5 Concentration Requirements for the Chemical Active Substance in Storage
37
Transport Environment
38
Table 4-6 Climatic Environmental Requirements in Transport
38
Operating Environment
39
Table 4-7 Concentration Requirements for the Mechanical Active Substance in Transport
39
Table 4-8 Concentration Requirements for the Chemical Active Substance in Transport
39
Table 4-9 Climatic Environmental Requirements During Operation
39
Table 4-10 Concentration Requirements for the Mechanical Active Substance in Operation
40
Table 4-11 Concentration Requirements for the Chemical Active Substance in Operation
40
5 Appendix
42
Lookup Table of Optical Module Parameters
42
Usfp
43
Table 5-1 Parameters of USFP+ Module
43
Dsfp
44
Table 5-2 Parameters of DSFP+ Module (10 Gbit/S, LC/PC, Dual-Fiber Bidirectional, 40 Km)
44
Table 5-3 Parameters of DSFP+ Module (10 Gbit/S, LC/PC, Dual-Fiber Bidirectional, 80 Km)
46
Rsp
47
Table 5-4 Parameters of RSP Module (10 Gbit/S, LC/PC, Dual-Fiber Bidirectional, 10 Km)
47
Table 5-5 Parameters of RSP Module (10 Gbit/S, LC/PC, Dual-Fiber Bidirectional, 20 Km)
48
Table 5-6 Parameters of RSP Module (10 Gbit/S, LC/PC, Dual-Fiber Bidirectional, 20 Km)
48
Table 5-7 Parameters of RSP Module (10 Gbit/S, LC/PC, Dual-Fiber Bidirectional, 40 Km)
48
Uqsp
49
Table 5-8 Parameters of the UQSP Module (41.2Gbit/S, LC/PC, Dual-Fiber Bidirectional)
49
Table 5-9 Parameters of the UQSP Module (41.2 Gbit/S, MPO)
49
Uqp
50
Bidirectional)
50
Table 5-10 Parameter of the UQSP Module (44.6 Gbit/S, MPO)
50
Table 5-11 Parameters of the UQP Module
50
Otu4
50
Uc2
51
Table 5-12 Parameters of the UC2 Module (103.1 Gbit/S and 111.8 Gbit/S, LC/PC, Dual-Fiber Bidirectional, Compatible with 100GE and OTU4)
51
Table 5-13 Parameters of the UC2 Module
51
Cables
52
Fiber
52
Figure 5-1 LC/PC Fiber Connector
52
Figure 5-2 MPO Fiber Connector
53
Figure 5-3 MPO-LC Branch Optical Fiber Jumper
54
Table 5-14 Wiring of the Fiber
54
Ethernet Cable
55
Figure 5-4 Ethernet Cable
55
Table 5-15 Wiring of EIA/TIA 568 a and EIA/TIA 568 B Standards
55
Figure 5-5 Wiring of the Straight-Through Cable
56
Figure 5-6 Wiring of the 100 Mbit/S Crossover Cable
56
Configuration Cable
57
Figure 5-7 Wiring of the 1000 Mbit/S Crossover Cable
57
Table 5-16 Technical Specifications of the Raisecom Straight-Through Cable
57
Power Cables
58
Figure 5-8 Configuration Cable
58
Figure 5-9 DC Power Cable
58
Table 5-17 Technical Specifications of the Configuration Cable
58
Table 5-18 Technical Specifications of the DC Power Cable
58
Figure 5-10 Stripping Dimensions and Connector
60
Figure 5-11 European AC Cable
60
Figure 5-12 American AC Cable
61
Table 5-19 Technical Specifications of the European AC Power Cable
61
Table 5-20 Technical Specifications of the American AC Power Cable
61
Ground Cable
62
Figure 5-13 Ground Cable
62
Figure 5-14 OT Terminal
62
Table 5-21 Technical Specifications of the Ground Cable
63
Table 5-22 Technical Specifications of the OT Terminal
63
Compliant Standards and Protocols
64
Terms
65
Acronyms and Abbreviations
67
4
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the Raisecom iTN8600-I and is the answer not in the manual?
Ask a question
Raisecom iTN8600-I Specifications
General
Brand
Raisecom
Model
iTN8600-I
Category
Marine Radio
Language
English