5.2.5 Ground cable
Two ground terminals are located on the right part of the left side and right part of the rear
panel, thus facilitating selection of grounding location.The ground cable is used to connect the
iTN8600-I to the ground.
Connecting the ground cable properly is an important guarantee to lightning
protection, shock proof, and anti-interference. When installing and using the device,
ensure that the ground cable is properly connected; otherwise, bodily injury or device
damage may occur.
Introduction
The ground cable is used to connect the iTN8600-I to the ground. There is a ground terminal
screw on the iTN8600-I panel. Press and connect one end of the ground cable with the OT
terminal. Use the screw to fix the OT terminal to the ground terminal. Connect the other end
of the group cable with the ground.
Appearance
The ground cable is composed of ground lugs and the coaxial cable. The ground lug is usually
an OT non-insulated terminal. The coaxial cable is a yellow/green multistrand copper soft
flame-retardant conducting wire. Figure 5-13 and Figure 5-14 show the ground cable and OT
terminal.
Figure 5-13 Ground cable
1
Conducting wire
2
Insulating sheath
3
OT terminal
Figure 5-14 OT terminal