- 19 -
V07 en, Basic_Installation_Accessories
Electric units:
The connection of the power cable is done via power input terminals.
L1, L2, L3 Grey terminals
N Blue terminal
PE
Life wire
Neutral wire (not used NA)
Protective ground
Yellow/Green terminal
L1 Live wire Brown, Black or Grey wire
N Neutral wire Blue wire
PE Protective ground Yellow/green wire
L2 (US/CA)
Live wire White/Brown
Electricity - Installation done correctly
Gas units: US 5-15P 120v cord and plug or 208/240v 6-15P cord and plug
The connection of the power cable for gas units is done
via 1/4" spade connectors to the integrated noise filter.
On floor units this noise filter is located behind the hand shower roll guide.
6 Electrical connection
Fuse [A]
60 61 62 11 12 21 22
2 AC 208V 50 60
2 AC 240V 50 70
3
AC 208V
30 35 70 60 125 125 200
3 AC 240V 30 40 80 75 150 150 250
3 AC 440V 20 35 30 60 60 100
3 AC 480V 25 40 35 70 70 110
AWG [x]
60 61 62 11 12 21 22
2 AC 208V 8 4
2 AC 240V 8 4
3 AC 208V 12 8 3 4 2 1 4/0
3 AC 240V 12 8 3 4 2 1 3/0
3 AC 440V 14 8 8 4 4 2
3
AC 480V
14 8 8 4 4 3
Maximum permissible tolerance for input voltage (see type label for input
voltage) is within the range of -15% to + 10%.
Use copper
wire only for power supply connections.
US/Canada 12/2018