Instruction for manual descaling
2
3
1
SCC or CM shall only be descaled when the cabinet tem-
perature is below 40°C (104°F)
Start cool down if required.
Empty and rell steam generator to cool it down. Now
empty steam generator manually into a bucket and
measure the volume of water drained from the
steam generator.
Descaler must ONLY be lled via the steam inlet port
found inside the interior cabinet!
Remove hinged rack (trolley) and swing air bae open.
Insert hose of descaler pump into steam inlet port inside
interior cabinet.
Do NOT fill through level electrode opening!
Damage to other components may occur!
Non compliance with this instruction can cause
damages to the unit!
Please observe the information on the material saey data sheets!
Protective clothing and tools required:
» Protective clothing: Goggles, gloves, apron
» Container with descaler
» Foot pump (6004.0203)