Additional information for manual descaling
Follow Instruction: “Descaling Steam generator” in the Trouble shooting manual!
In order to determine the amount of scale inside the steam generator manually drain and measure the
volume of water from the steam generator.
The steam generator should be descaled when less than the below listed volumes are drained from
the steam generator:
1 liter = 0.264gal (US); 1gal (US) = 3,78 liter; 4,5 liter = 4,5 x 0,264 = 1,19 gal(US)
CALC NORM
Unit size Descale if less than
below volume is
drained
Required volume of
descaler
Volume of clean
steam generator
SCC/CM
Electric units
60 1,4 l 1,7 l 1,7 l
61 2,7 l 4,0 l 3,6 l
62 4,5 l 8,0 l 6,0 l
101 4,7 l 8,0 l 6,2 l
102 6,4 l 11,5 l 8,5 l
201 6,8 12,0 l 9,0 l
202 8,7 l 14,6 l 11,6
SCC/CM
Gas units
61 Gas 3,0 l 4,0 l 4,0 l
62 Gas 4,5 l 8,0 l 6,0 l
101 Gas 5,3 l 8,0 l 7,0 l
102 Gas 6,8 l 11,5 l 9,0 l
201 Gas 6,0 l 12,0 l 8,0 l
202 Gas 8,3 l 14,6 l 11,0 l
CPC/CM
Electric units
61 2,4 l 4,0 l 3,2 l
101 4,0 l 7,0 l 5,0 l
102 6,5 l 11,0 l 7,7 l
201 6,9 l 12,0 l 8,1 l
202 9,6 l 15,0 l 11,0 l
CPC/CM
Gas units
61 Gas 2,6 l 4,5 l 3,6 l
101 Gas 4,8 l 8,0 l 6,0 l
102 Gas 4,9 l 8,0 l 6,1 l
201 Gas 4,9 l 8,0 l 6,1 l
201 Gas 7,2 l 12,0 l 8,4 l
Classic-
Line
Gas units
CM 62 Gas 3,5 l 6,0 l 5,5 l
CM 101 Gas 3,5 l 6,0 l 5,5 l
CM 201 Gas 7,0 l 12,0 l 11,0 l
Classic-
Line
electric units
CD/CM/CC 6 2,5 l
CD/CM/CC 101 4,0 l
CD/CM/CC 201 7,0 l
CD/CM/CC 20 10,0 l