Preventive maintenance
1/2
Preventive maintenance (Checklist)
Customer name: Company:
Street: Town/Country:
Telephone: E-Mail:
Serial number
unit/UltraVent
Soware
version:
Regular maintenance*
Complaint?
Yes: No: Comment, in case of a complaint:
Maintenance preparation:
- Service data and HACCP data copied to USB stick
- Unit soware is up-to-date
- There are no service or gas errors in the service history
- No grease / no dirt in the water drain
Cabinet door maintenance:
- Cabinet door, door glas and door settings are ok
- Door gasket and gasket for mobile oven rack are without damage
Interior cabinet check:
- All parts of the interior cabinet are undamaged, correctly installed and
working
Water supply / drain maintenance:
- Water distribution is leak tight, water entrance lter is clean and valves
are working
- Pumps and add-on pieces are working and leak tight
- Every component of the control box is working and clean
Steam generator maintenance:
- Steam generator and every associated part is working
- Steam pipe from SG to exhaust hose is functional and tight
Electrical maintenance:
- Electrical wiring faultless (clamps xed and isolation faultless)
- Steam heating and hot air heating are working
- Maximum pcb temperature entered to comment fiel
- Amp draw hot air (at 100%) in case of electrical units:
L1: A L2: A L3: A
- Amp draw steam (at 100%) in case of electrical units:
L1: A L2: A L3: A
Control panel maintenance:
- Control panel is working and tight
- All control elements are undamaged and working
Exhaust hood / UltraVent maintenance:
- Air lter installed and clean
- UltraVent is working and lter clean (if UltraVent installed)
- Distance between unit top edge and exhaust hood lower edge / ceiling
entered to comment fiel
Unit care instruction:
- Instruction CleanJet / Care
- Care and Cleaning of unit parts and unit components
Instruction of company technicians:
- Replacement of lter and door gasket
- Descale of the moistening valve
Only in case of gas units
Gas component maintenance:
- Gas components / gas connections are working and tight
- Flue gas analysis done and values in the permitted range
- External exhaust hood checked
*„Light“ User 1x per year / „Medium“ User 1-2x per year / „Intensive“ User 2-3x per year (for details see detail list)