V07 en, Basic_Installation_Accessories - 18 -
Electricity - Installation done correctly
Electrical connection has to be done according to the local rules and regulations.
All electric units 61 – 202 are shipped without electrical cable. XS 60 are shipped with with cable and angled plug: 1ph
208 and 1ph 240: 6-50P,
3ph 208 and 3ph 240: 15-30P
All gas units 61 – 202 are equipped with a power supply cable (14AWG) 120v 61,101, 201 5-15P, 208v ALL 6-15P
Should you need to change this cable, an oil resistant, coated, exible cable must be used. The wire gauge must be
selected according to the the cable lenght and the power rating table below.
Unit size Connected electrical power
Electric units
Connected electrical power
Gas units
60 5,7 KW
61 11,0 KW 0,4 KW
62 22,3 KW 0,77 KW
101 18,6 KW 0,5 KW
102 36,7 KW 0,8 KW
201 37,0 KW 0,95 KW
202 65,5 KW 1,6 KW
Electric units:
Type Power rating Kw Electricity consumption A
60 61 62 101 102 201 202 60 61 62 101 102 201 202
3 AC 208V
5.7 11.1 22.1 19 37 38 68 16 31 61 53 102 105 189
3 AC 240V
5.7 11.1 22.1 19 37 38 68 18 35 71 61 118 121 218
3 AC 440V
11.1 22.1 19 37 38 68 14.6 33 24.9 48 49 84
3 AC 480V
11.1 22.1 19 37 38 68 15.8 36 27 53 54 97
2 AC 208V
11.1
2 AC 240V
5.7
11.1 32 61.4
Pulsed?
No
Yes
No
Yes
No
Yes
SSR's
5.7
28
53.4
Gas units:
Type Power rating Electricity consumption A
61 62 101 102 201 202 61 62 101 102 201 202
- - - - - -
- - - - - -
1NAC 120V 0.4 -NA 0.5 -NA 0.95 -NA 3.4 -NA 4.2 -NA 7.9 -NA
1AC 208V USA 0.4 0.77. 0.5 0.8 0.95 1.6 1.92 3.7 2.4 3.85 4.57 7.69
1AC 240V USA
0.4 0.77. 0.5 0.8 0.95 1.6 1.67 3.21 2.08 3.33 3.96 6.67
Note: 61,101,201 gas are standard as 120v and can be special ordered as 208/240v
62/102/202 gas are NOT available in 120v power!
US/Canada 12/2018