Electrical connection
6.6 Voltage Conversion
208/240V units
All electric units and 62/102/202 gas units are set to 208V from factory. They can be converted to 240V.
To convert from 208V
to 240V proceed as follows:
> Disconnect unit from mains
> Remove left side panel and open operator
control panel.
> Set power switch S13 to desired voltage (208
or 240V)
> On Electric units the control transformer T1 change connection to the desired voltage input (208v or 240v)
> In the starter kit of the unit there is a sticker
which has to be filled in after voltage conversion. After filling it in put
the sticker next to the name plate.
S 13
XS60
61-202E
440/480 V units
Units are set to 480V ex works, but can be converted to 440V.
To convert from 480V
to 440V proceed as follows:
> Disconnect unit from mains
> Remove left side panel and open operator
> Remove adapter cable W22 from input transformer T3 and plug X72
> Connect plug X72 to transformer T3.
> Set power input switch S13 to 440 V
Gas
208/240v
units also
20
V07 en, Basic_Installation_Accessories
US/Canada 12/2018
Drain - Installation done correctly
•
Drain connection must be done using a 50mm
(2“) steam temperature (1 1/2" XS60)
resistant pipe.
• Reducing the diameter is not allowed.
• Flexible hoses shall not be used as they can
buckle and bend.
The average waste water temperature is
65°C(149°F).
Water / Drain connection kits (water hose and set of drain pipes etc. are available)
Direct Drain is typically not
allowed in NA building codes,
consult local authorities.