V07 en, Basic_Installation_Accessories - 16 -
Water connection ¾“, connection hose ½“ minimum
Dynamic water pressure: 150 – 600 kPa, 1,5 – 6 bar, 22 – 88 psi
1 – Common cold water connection max 30°C (86°F)
Dual water connection: standard and treated water, only 61-202
2 – Cold water connection max 30°C (86°F)
3 – Treated, ltered water max 30°C (86°F), (all except quenching)
61 – 102 201 - 202
Water connection hose 13mm (½“) minimum
needed water quantity for correct operation of solenoid valves:
60,
61, 101:
62, 102, 201, 202:
7L/min 2 gpm
20L /min 5.2 gpm
25L /min 6.6 gpm
(Water / Drain connection kit - water hose and set of drain pipes 50mm for 61-202: 60.70.464 (European)
Average water consumption (for water lter dimensioning):
Unit size Total consumption per hour connection 1
without handshower and Cleanjet
Consumption of treated water connection 3 per
hour (without control solenoid Y2)
60 6,0L / 1,6gal --
61 10,2 L / 2,7gal 3,0 L / 0,8gal
62 25,6 L / 6,7gal 8,0 L / 2,1gal
101 18,3 L / 4,8gal 6,3 L / 1,7gal
102 33,0 L / 8,7gal 10,4 L / 2,7gal
201 39,9 L / 10,5gal 12,5 L / 3,3gal
202 49,0 L / 12,9gal 15,0 L / 3,9gal
Water - Installation done correctly
max 30°C
(86°F)
150-600kPa
21-87 psi
SCC_XS
1
US/Canada 12/2018