Chapter 3: Installation 31
If the existing cable is too short, please order from the following:
Connecting to an open array
If you are using an open array, this cannot be powered through the display. You will
need to purchase a split pedestal cable or open array package and connect the array
and display as shown:
...for new installations
Part No. Cable length Weight Radome power output
E55065 15m Heavy 2Kw or 4 Kw
E55066 25m Heavy 2Kw or 4 Kw
E55067 10m Light 2kw
E55068 15m Light 2kw
Radome inter-unit cable for use with the C Series display
To display or extension
(power supplied via display unit)
To Radome Scanner
D6909-1
RANGE
CANCELOK
PAGE
ACTIVE
WPTS/
MOB
MENU
DATA
IN
OUT
D6618-2
Open Array
Boats DC
Power Supply
C-Series Display
Power to display
Power to open array
Split pedestal cable
(15 or 25 metres)
Note: The power supply for both the display
and the open array must be of the same
voltage and from a common supply source
e.g the same battery or power breaker.