13.R
epeatsteps7to11foreachCalibrationpointyouwanttoadd.
ThemoreCalibrationpointsyouaddthehighertheaccuracyofLogspeedwillbe.
Note:
Ifthete
xtappearsredthenthenewreadingdeviatestoofarfromthestoredreading.Y ouwill
needtoaddaCalibrationpointclosertothestoredreadingatryagain.
EditingaCalibrationpoint
ExistingCalibrationpointscanbeedited.
Fromthe
Advancedmenu:
1.Select
Adjustcaltable.
2.SelectStart.
3.HighlighttherelevantCalibrationpointfromthetable.
4.Select
Options.
5.Select
Editcalpoint.
TheCalibrationpointadjustmentpageisdisplayed.
6.Usethe
Upand DownbuttonstoadjusttheCalibrationpointfortheselectedspeedtomatch
yournewCalibrationspeed.
7
.Select
DonetoreturntotheCalibrationtable.
8.Repeatsteps4to7forallCalibrationpointsthatrequireadjustment.
9.Select
FinishwhenalloftherequiredCalibrationpointshavebeenadjusted.
DeletingaCalibrationpoint
CalibrationpointscanbedeletedfromtheCalibrationtable.
Fromthe Adjustcaltablemenu:
1.Select Start.
2.HighlighttheCalibrationpointyouwanttodelete.
3.Select
Options.
4.Select
Yestodelete.
TheCalibrationpointisdeletedfromtheCalibrationtable.
ResettingtheCalibrationtable
TheCalibrationtablecanberesettofactorydefaultvaluesbyfollowingthestepsbelow:
FromtheAdvancedMenu:
1.Select Resettodefaults.
2.Select
Yes.
3.Select OK.
TheCalibrationtableisresettofactorydefaultvalues.
EnteringanewCalibrationtable
AnewCalibrationtablecanbeaddedmanually.ThenewCalibrationtablewillreplacetheexisting
tablewhichisdeleted.Thisisusefulwhenyouhavebeenprovidedaspecificcalibrationtable
foryourhulltype.
Note:
Y ouwillneedtoworkoutyourCalibrationfactorsforeachCalibrationpointbeforeyoucancreate
thenewCalibrationtable.
Fromthe Advancedmenu:
1.Select
Enternewcaltable.
2.SelectStart.
AllexistingCalibrationpointsaredeletedandyouwillbepromptedtoenternewCalibration
points.
T ransducercalibration33