67
RC GROUP - 149_ItEn.0102
CONFIGURAZIONE UNITA
UNIT CONFIGURATION
Premere per 4 secondi
HOME
1
PRG
3
Press for 4 seconds
quindi inserire Password
than digit Password
ON DISPLAY TIPO DI SET
SET TYPE
DEFAULT RANGE SYMBOL
Clock board scheda orologio
clock board
N N - Y
Supervisor code codice supervisione
supervisor code
0 00 ÷ 99
Supervisor mode modo supervisore
supervisor mode
R R - R/W
Probe selction selezione sonda
probe selection
Supply air temp. temperatura mandata aria
supply air temperature
N N - Y
Outl. water temp. uscita acqua refrigerata
outlet water temperature
N N - Y
Ext. air temp. temperatura aria esterna
external air temperature
N N - Y
Inlet water temp. ingresso acqua refrigerata
inlet water temperature
N N - Y
Room humidity umidità ambiente
room humidity
N N - Y
Integr. humidif. umidificatore integrato (*)
integrated humidifier (*)
N N - Y
Pressure probe present presenza sonda di pressione
pressure probe present
N N - Y
Min. scale scala minima pressione
min pressure scale
0 kPa ± 500 kPa
Max. scale scala massima pressione
max pressure scale
3000 kPa 0÷5000 kPa
Analog input 7 used like ingresso analogico 7 usato come (*)
analog input 7 used like (*)
not used not used
voltage line
line current
ext. compens.
(*) con Integr. humidif. Y è utilizzato in
(*) with Integr. humidif. Y it is automatically
automatico per corrente umidificatore e
used for humidifier current measurement
questo set non viene visualizzato.
and this set is not displayed
Analog input 8 used like ingresso analogico 8 usato come
analog input 8 used like
not used not used
voltage line
line current
ext. compens.
conductivity
Voltage line max scale scala massima tensione linea
max voltage line scale
600 V 0÷700 V
Line current max scale scala massima corrente linea
max line current scale
100 A 0÷700 A
Configuration configurazione unità
unit configuration
2 compr. - 2 circ. - 2 board ——
2 compr. - 1 circ. - 2 board ——
2 compr. - 1 circ. - 1 board ——
1 compr. - 2 board ——
1 compr. - 1 board ——
0 compr. - 2 board ——
0 compr. - 1 board ——
Unit no. present numero unità presenti in rete
units no. present in network
1 1 - 2 - 3 - 4
Heater no. numero stati riscaldamento elettrico
heaters step number
0 0 - 1 - 2 - binary
Unloader comp. parzializzazione compressore
unloader compressor
N N - Y
En. double speed compressore doppia velocità
double speed compressor
N N - Y
Analog input 7 board 2 used as ingresso analogico 7 board 2 usato come
analog input 7 board 2 used as
Line current corrente di linea
line current
N N - Y
Max. scale scala massima corrente
max current scale
100 A 0÷500 A
Analog input 8 board 2 used as ingresso analogico 8 board 2 usato come
analog input 8 board 2 used as
Voltage line voltaggio di linea
voltage line
N N - Y
Max. scale scala massima tensione
max voltage scale
600 V 0÷700 V
Analog output 1 uscita analogica xY0
analog output xY0
cooling valve cooling valve xY0
heating used
not used
cooling + freecooling
cool valve +dehumid
Cooling fl. valve valvola 3 punti raffreddamento ad acqua
cooling floating valve (water)
N N - Y
Heating fl. valve valvola 3 punti riscaldamento ad acqua
heating floating valve (water)
N N - Y
MP2000 AIR CONDITIONERS
Software per condizionatori d'aria EPROM CZX....
Software for air conditioners