LIFTLOG 1000 INSTALLATION AND CALIBRATION
30
Load Calibration Settings only
Calibration settings are contained in a .HEX file with the default name "Al10Nvm.HEX".
These settings include calibration settings, Sensor setup and most user settings made in the 'Setup' menu.
NOTE: Calibration settings do not include store names, store references and “Instrument ID”, which can be uploaded separately from
.TXT files.
Typically you may have a number of .HEX files for different machines (named accordingly), saved from previously installed
instruments. Select the appropriate .HEX file from the list displayed and press to upload.
"Text"
Load the Store descriptions, Store references for all Stores and the “Instrument ID” text. This file does not include calibration
settings
Select the "Strings.txt" file from the list displayed and press to upload.
3.3.9 Overload Log
This screen displays the last 10 overload events. After the 10
th
overload, the
oldest log entry is deleted.
An overload is logged when the overload pressure limit (3.4.5) is exceeded for
longer than the “Overload Log Delay” time programmed in the Sensor Setup
menu. An overload is logged whether or not the load is weighed.
Press to export via USB.
Press to print out.
UK796-370.JPG