LIFTLOG 1000 INSTALLATION AND CALIBRATION
31
3.4 Factory Level Settings
Select then to access the Factory Level Menu (default PIN = 4084).
3.4.1 ‘Auto’ Weight Calibration
1. From the “Calibration“ screen, select ‘Auto’ and press .
2. Zero weigh Lift the empty forks to the weighing position and press .
The zero point is calculated and displayed as a % of maximum pressure.
3. Enter the known weight of the calibration load. This should ideally be near
the maximum weight capacity in order to calculate the most accurate
calibration factor.
4. Lift the calibration load to the weighing position and press .
5. The new calibration factors are calculated and stored in memory. All the
weight calibration factors can be viewed or manually edited by selecting
Manual’ from the “Calibration” screen.
UK796-380.JPG
UK796-390.JPG