Safety
Information to the user
In all applications involving the use of machine tools, eye protection is recommended.
The LP2 system must be installed by a competent person, observing relevant safety precautions. Before
starting work, ensure that the machine tool is in a safe condition with the power switched OFF and the
power supply to the HSI-C / HSI / MI 8-4 is disconnected.
Refer to the machine supplier’s operating instructions.
Information to the machine supplier / installer
It is the machine supplier’s responsibility to ensure that the user is made aware of any hazards involved in
operation, including those mentioned in Renishaw product literature, and to ensure that adequate guards
and safety interlocks are provided.
If the probe system fails, the output signal may falsely indicate a probe seated condition. Do not rely on
probe signals to halt the movement of the machine.
Information to the equipment installer
All Renishaw equipment is designed to comply with the relevant UK, EU and FCC regulatory requirements.
It is the responsibility of the equipment installer to ensure that the following guidelines are adhered to, in
order for the product to function in accordance with these regulations:
any interface MUST be installed in a position away from any potential sources of electrical noise (for
example, power transformers, servo drives);
all 0 V/ground connections should be connected to the machine “star point” (the “star point” is a single
point return for all equipment ground and screen cables). This is very important and failure to adhere
to this can cause a potential difference between grounds;
all screens must be connected as outlined in the user instructions;
cables must not be routed alongside high current sources (for example, motor power supply cables),
or be near high-speed data lines;
cable lengths should always be kept to a minimum.
Equipment operation
If this equipment is used in a manner not specied by the manufacturer, the protection provided by the
equipment may be impaired.

Table of Contents

Other manuals for Renishaw LP2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Renishaw LP2 and is the answer not in the manual?

Renishaw LP2 Specifications

General IconGeneral
BrandRenishaw
ModelLP2
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals