Step 12. Inspection
Check and confirm all wires are firmly fastened to the inverter charger.
Step 13. Install the Cover
N-G Bonding Relay
The inverter charger is equipped with a Neutral to Ground bonding relay that ensures that either the neutral in
or out contact of the RV is always grounded.
This helps prevent electrical shock caused by contact between the neutral contacts of the RV and external AC
power sources.
By default, the Neutral to Ground bonding relay is enabled when the inverter is shipped from the factory. To
disable the relay function, remove the N-G bonding relay screw.
N L2
AC OUT
L1 N L2
AC IN
L1
BAT-
BAT+
N L2
AC OUT
L1 N L2
AC IN
L1
BAT-
BAT+
Enabled Disable

Other manuals for Renogy REGO

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Renogy REGO and is the answer not in the manual?

Renogy REGO Specifications

General IconGeneral
Output Voltage12V/24V
Output Current20A
Charging AlgorithmMulti-stage (Bulk, Absorption, Float)
Battery CompatibilityFlooded, Lithium
Operating Temperature-20°C to 50°C
ProtectionOver-voltage, Short-circuit, Reverse polarity