26
The zone LED corresponding to the current operating
mode will illuminate.
Zone 1 LED Personal Attack (PA)
Zone 2 LED Intruder
Zone 3 LED 24 Hour Intruder
Zone 4 LED Fire
Zone 5 LED Test
To change the setting:
Press the key corresponding to the required zone
operating mode, the corresponding zone LED will
illuminate as the setting is changed.
Press to save the new setting and exit to
Program Mode, or
Press to exit without saving.
OPERATING
INSTRUCTIONS
When leaving the premises, the system must be
Armed. However, before doing so, check that all
windows are closed and locked, all protected doors are
closed and PIR Detectors are not obstructed. Ensure
that pets are restricted to areas not protected by PIR
Detectors.
The system has 2 armed modes, ARM and PART-ARM.
The Part-Arm facility allows for selected zones to be left
disarmed whilst the remainder of the system is Armed.
When the system is Armed (in either mode) the Zone
LEDs for all active zones will illuminate for a few
seconds. Also the appropriate Arming Mode LED will
ash. All active zones set as INSTANT will immediately
be Armed and will be able to trigger an alarm. If
enabled, the system exit-delay will start and the Control
Panel will start beeping, (the beep rate increasing in
steps as the delay period expires). When the exit-delay
expires all active zones set to ‘Delay’ will be Armed and
able to trigger an alarm. By this time the user must
have left the property and closed the nal protected
door.
If while the system is armed a detector on an INSTANT
zone is triggered then this will immediately trigger an
Alarm with both the Control Panel and Siren sounding.
However, if a detector on a DELAY zone is triggered,
the entry-delay (if enabled) will start and the Control
Panel will start beeping with the beep rate increasing
in steps as the delay expires. If the system has not
been Disarmed when the entry-delay period expires,
the Alarm will sound. When an Alarm occurs the LED
corresponding to the zone that triggered the alarm will
ash.
At the end of the programmed alarm duration the Siren
and Control Panel alarms will stop and the system will
automatically re-arm itself, (subject to the conditions of
the Zone Lockout feature).
Notes: - To conserve power and maximise battery
life the PIR detector will only detect movement if there
has been no movement detected within the previous 2
minutes.
- If the Solar Siren is tted and the 3 minute limit is
enabled then the siren will stop when the programmed
alarm duration expires or after 3 minutes, whichever
occurs rst.