LED on Magnetic Contact Detector illuminating when
door or window is opened
1. Low battery - replace batteries.
If you have any problems with your alarm, please
call the Helpline on:
01268 563273
(Lines open 9.00am to 5.00pm, Monday to Friday)
4. Ensure DIP switches 1, 2 and 3 of SW3 are correctly
set according to the required zone.
5. Ensure that detector is mounted the correct way up, (i.e.
with detection window at the bottom).
6. Ensure that the detector is mounted at the correct
height, (i.e. 2-2.5 metres).
7. Allow up to 3 minutes for detector to stabilize and
become fully operational. Leave the area for this period.
8. Ensure detector is within effective radio range of the
Control Panel and is not mounted close to metal objects
which may interfere with Radio transmission.
PIR Detector LED ashes on detection of movement,
(device in normal operation mode).
1. Ensure that the detector is set for normal operation, (i.e.
DIP switch 4 of SW3 is OFF).
2. Low battery - replace battery.
Magnetic Contact Detector not working.
1. Ensure that Magnet is correctly positioned in relation
to Detector and that the gap between Magnet and
Detector is less than 10mm.
2. Ensure batteries are tted with correct polarity (correct
way around).
3. Ensure battery holder connections are making good
contact with the batteries and Circuit Board.
4. Ensure ‘House Code’ is correctly set to the same code
as all other system devices.
5. Ensure DIP switches 9, 10 and 11 are correctly set
according to the required zone.
6. If there is no additional wired Magnetic Contact
connected, ensure jumper link is tted.
7. If an additional wired Magnetic Contact is connected:
a. Ensure jumper link is removed.
b. Check that both contacts are closed.
c. Check that additional contact is correctly
wired.
Note: If an additional contact is used then the doors/
windows protected by both the main wirefree detector
and the additional wired detector must be closed when
either is opened. If one of the doors/windows is already
open then the opening of the other door/window will not
be detected.
8. Ensure detector is within effective radio range of Control
Panel and is not mounted close to metal objects which
may interfere with Radio transmission.
Magnetic Contact Detector false alarming
1. Ensure that magnet is correctly positioned in relation to
detector.
2. Ensure that gap between magnet and detector is less
than 10mm.
3. Tamper switch below battery cover is not depressed -
check battery cover is tted correctly and that xing lugs
are not broken.