Company Registered in England No: 4167649 VAT Registration No: 732 5692 25 BS EN ISO 9001:2008 No: LRQ 0964389
+44 (0)1204 699959
enquiries@hyquip.co.uk
Hyquip Limited New Brunswick Street Horwich Bolton Lancashire BL6 7JB UK
www.hyquip.co.uk/web/index
48/60 Maintenance and repair
Bosch Rexroth AG, RE 92100-01-B/09.2012 Series 10, 11 and 30,
10 Maintenance and repair
NOTE
Inspection and maintenance work carried out too late!
Damage to equipment!
▶ Carry out the specified inspection and maintenance work at the intervals
described in this manual.
10.1 Cleaning and care
NOTE
Damage to seals and electrical system by mechanical effects!
The water jet of a power washer may damage the seals and electrical system of the
axial piston unit!
▶ Do not point the power washer at sensitive components, e.g. shaft seal,
electrical connections and components.
For cleaning and care of the axial piston unit, observe the following:
▶ Check whether all seals and fittings on the connections are securely seated to
ensure that no moisture can penetrate into the axial piston unit during cleaning.
▶ Use only water and, if necessary, a mild detergent to clean the axial piston unit.
Never use solvents or aggressive detergents.
▶ Remove coarse external dirt and keep sensitive and important components, such
as solenoids, valves, indicators and sensors, clean.