Facsimile Features
120
4
Programming Changing and Deleting a
Scan Size
This section describes how to program, change, and delete a Scan Size.
When you select a scan size to scan a custom size original, two custom sizes are
available (Program Size 1 and Program Size 2). Use these functions to program
a custom size in advance.
To change an existing scan size, just use the same procedure.
Important
When programming or changing a scan size, it is recommended that you
make a record of the new size.
You can program up to two sizes.
Specify a horizontal length from 128 to 1200 mm, or from 5.5 to 47 inches.
A Press [Facsimile Features].
B Press [Administrator Tools].
C Press [Program / Change / Delete Scan Size].
D Select [Program Size 1] or [Program Size 2].
E Enter a horizontal size using the number keys.
Each time you press [mm] or [inch], the units switch between “mm" and
“inch". If you enter a length and press [mm] or [inch], the length is converted
automatically according to the unit (fractions are rounded off). For example,
when you enter {2}, {2}, and {0} in millimeters and change to “inch", the
length “8.7 inch" is shown on the display. If you press [mm] or [inch] again,
“221 mm" is displayed.
If you make a mistake, press [Clear] or the {Clear/Stop} key, and then try again.
To cancel a scan size, press [Cancel].