SC Tables
SM 6-3 D127/D128
Trouble
shooting
No.
Definition
Symptom Possible Cause
142 B
White level correction error
The automatic adjustment has
failed to correct a current white
level to the certain level.
Dewing scanner unit
Defective scanner drive
Defective optical section
Defective SBU board
Defective relevant harness
144 B
SBU Communication Error
Cannot correctly establish
communication with the SBU.
Defective relevant harness
Defective destination device
(e.g., BICU, etc)
Defective SBU
161 IPU error
-001 B
LSYNC error
Detecting an error from the result of
the IPU self-check on startup.
Defective the IPU or the BICU
(or bad connection between the
ASIC and the LEO, LSYNC
Abnormal, etc)
Cable bad connection between
the SBU and the IPU (or the
BICU).
-002 B
RI response error
Detecting an error on access to the
RI.
Defective the IPU (the BICU, the
ICTL) or RI abnormal
performance, etc