System Service Mode
SM Appendix 3-3 D127/D128
Appendix:
SP Mode
Tables
1105 14
Thresh: S1 [0 to 50 / 16 / 1 °C/step]
Sets standard temperature used for the environment judge.
*About the judge, refer to SP1105-015.
1105 15
Thresh: delta t [0 to 50 / 0 / 1 °C/step]
The environment judge takes place as follows:
Compared with “S1” and “S1+Delta t”, the environment temp. is…
(S1: SP1105-014 value / Delta t: This SP’s value)
S1 Less or equal Greater Greater
S1+Delta t Less Less or equal Greater
Judged as Low temp. Normal temp. High temp.
1105 16 Low: Plain1 [0 to 30 / 5 / 1 °C/step]
Sets the additional degree for each
paper type printing under low
temperature environment.
*Refer to SP1105-
015 about the
environment judge.
1105 17 Low: Plain2
1105 18 Low: M-Thick
1105 19 Low: Thick
[0 to 30 / 10 / 1 °C/step]
The same function as SP1105 (-017 to
-18)
1105 20 Registration Waiting: Plain1
[0 to 1 / 1 / 1 /step]
(0: OFF / 1: ON)
Registration waiting means keeping fed
paper in the registration part until fusing
unit is ready to work.
1105 21 Registration Waiting: Plain2
1105 22 Registration Waiting: M - Thick
1105 23 Registration Waiting: Thick
1105 24 Waiting: Center Minus: Plain1 [0 to 60 / 30 / 1 °C/step]
Subtracting temp. applying to
SP1105-001,002. The sum at which or
less, registration waiting starts.
1105 26 Waiting: Center Minus: Plain2