Bit Switches
SM Appendix 5-43 D127/D128
Appendix:
Fax Trouble-
Shooting
Guide
6-7
Available unit of resolution in
which fax messages are
received
Bit 7: 0, Bit 6: 0 = mm
Bit 7: 0, Bit 6: 1 = inch
Bit 7: 1, Bit 6: 0 = mm and inch
(default)
Bit 7: 1, Bit 6: 1 = Not used
For the best performance, do not change the
factory settings.
The setting determined by these bits is informed to
the transmitting terminal in the pre-message
protocol exchange (in the DIS/NSF frames).
Communication Switch 15 Not used (do not change the settings)
Communication Switch 16 Not used (do not change the settings)
Communication Switch 17 [SP No. 1-104-024]
No FUNCTION COMMENTS
0
SEP (Selective polling)
reception Enabled/Disabled
switch
0: Disabled / 1: Enabled
“Enabled” means SEP (Selective polling) is
acceptable on reception.
1
SUB (password-locked data)
reception Enabled/Disabled
switch
0: Disabled / 1: Enabled
“Enabled” means SUB confidential transmission is
acceptable on reception.
2
PWD (password) reception
Enabled/Disabled switch
0: Disabled / 1: Enabled
“Enabled” means PWD (password for SEP) is
acceptable on reception.
3-4 Not used Do not change the settings.
5
PSTN dial-in routine
Enabled/Disabled switch
0: Disabled / 1: Enabled
Determines whether PSTN dial-in routine function
by which reception information is transferred to
some destinations, enabled/disabled.
PSTN dial-in number is 4 digits.
6 Not used Do not change the settings.