Transport Belt Charge Adjustments
J007/J010/J011 4-38 SM
Print Wave Form: Mj4
Table 3-6 Mj4 Temperature/Humidity Table
**T919
The functions to adjust each table are in SP1200 to SP1231 (Engine Maintenance Mode).
The settings are stored in NVRAM on the main control board after they adjusted and
remain in effect after the machine is cycled off/on.
Table 3-9 Mj1 Temperature/Humidity Table
Factory Default Settings: All "0"
SP
No.
Menu Title Meaning SP No.
1200 CHG:PITCH:A1 Charge ID Table: Less than 10% Humidity (Mj1) 1200
1201 CHG:PITCH:A2 Charge ID Table: 10% to 25% Humidity (Mj1) 1201
1202 CHG:PITCH:A3 Charge ID Table: 25% to 35% Humidity (Mj1) 1202
1203 CHG:PITCH:A4 Charge ID Table: 35% to 45% Humidity (Mj1) 1203
1204 CHG:PITCH:A5 Charge ID Table: 45% to 55% Humidity (Mj1) 1204
1205 CHG:PITCH:A6 Charge ID Table: 55% to 65% Humidity (Mj1) 1205
1206 CHG:PITCH:A7 Charge ID Table: 65% to 75% Humidity (Mj1) 1206
1207 CHG:PITCH:A8 Charge ID Table: More than 75% Humidity (Mj1) 1207
1208 CHG:PITCH:B1 Charge ID Table: Less than 10% Humidity (Mj2) 1208
1210 CHG:PITCH:B3 Charge ID Table: 25% to 35% Humidity (Mj2) 1210
1211 CHG:PITCH:B4 Charge ID Table: 35% to 45% Humidity (Mj2) 1211
1212 CHG:PITCH:B5 Charge ID Table: 45% to 55% Humidity (Mj2) 1212
1213 CHG:PITCH:B6 Charge ID Table: 55% to 65% Humidity (Mj2) 1213
1214 CHG:PITCH:B7 Charge ID Table: 65% to 75% Humidity (Mj2) 1214
1215 CHG:PITCH:B8 Charge ID Table: More than 75% Humidity (Mj2) 1215
1216 CHG:PITCH:C1 Charge ID Table: Less than 10% Humidity (Mj3) 1216
1217 CHG:PITCH:C2 Charge ID Table: 10% to 25% Humidity (Mj3) 1217