J007/J010/J011  18  Repair Center Manual 
SC984 DRV circuit temperature abnormal 
Description: The temperature of the DRV board (driver board) is out of range (-13C to 
+55C). 
Probable Cause: The signal from the temperature sensor on the control board did not 
change. 
Location: Control board 
Procedure: 
1.  Cycle printer on/off, check result. 
2.  Check fan operation. 
3.  Replace control board. 
SC986 Humidity sensor abnormal 
Description: An abnormality was detected in the humidity sensor. 
Probable Cause: Defective temperature/humidity sensor. 
Location: Control board 
Procedure: 
1.  Cycle printer on/off, check result. 
2.  Check control board connections. 
3.  Replace control board. 
SC988 Air sensor abnormal 
Description: Air sensor was detected abnormal when suction was applied 3 times after the 
printer was powered on for the first time for ink tank filling or print head refreshing, but no air 
was detected. 
Probable Cause: Defective plunger prevented the air release value from depressing 
properly. 
Location: Air sensor of the affected print head. 
Procedure: 
1.  Replace the air release lever solenoid. 
SC990 Ink level sensor feeler out of position 
Description: One or more of the following occurred: 
  The ink level sensor feeler was not detected at initial ink filling or when air was purged 
from the ink tanks before filling. 
  The proper air pressure inside the ink tank could not be achieved. 
  The signal from the ink level sensor did not change.