71: [Txt Ppr: AC Duty Cycl of Ppr Trns Vltg]
Adjust the duty cycle of the AC voltage applied to the paper when Textured Paper mode is enabled.
Press [+] to increase the duty cycle and [−] to reduce it.
Setting Items Max. Value Min. Value Step Unit
[Txt Ppr: AC Duty Cycle of Paper Transfer
Voltage]
50 5 1 %
72: [Txt Ppr: Ppr Trns Isolatn Voltag: Side 1]
Adjust the separation voltage for paper transfer applied to Side 1 when Textured Paper mode is
enabled.
Press [+] to increase the voltage and [−] to reduce it.
Setting Items Max. Value Min. Value Step Unit
[Txt Ppr: Ppr Trns Isolation Voltage: Side 1] 12.0 0.0 0.5 KV
*
You can adjust the value in steps of 0.1 kV using from Web Image Monitor.
73: [Txt Ppr: Ppr Trns Isolatn Voltag: Side 2]
Adjust the separation voltage for paper transfer applied to Side 2 when Textured Paper mode is
enabled.
Press [+] to increase the voltage and [−] to reduce it.
Setting Items Max. Value Min. Value Step Unit
[Txt Ppr: Ppr Trns Isolation Voltage: Side 2] 12.0 0.0 0.5 KV
*
You can adjust the value in steps of 0.1 kV using from Web Image Monitor.
Fuser Adjustment
74: [Fusing Heat Roller Temperature Adj]
Adjust the heat roller temperature.
Press [+] to increase the temperature and [−] to reduce it.
Setting Values
105

Other manuals for Ricoh Pro C5110S