1.SC Codes
156
Error Name/Error Condition/Major Cause/Solution
Replace the Junction Gate Motor (proof/shift tray), reconnect the connectors.
Replace the JG HP Sensor (proof/shift), reconnect the connectors.
Replace the harness.
Replace the Main Board.
Resolve the mechanical failure for the junction gate mechanism (proof).
Error Name/Error Condition/Major Cause/Solution
Junction Gate Motor Error 2 (Staple JG)
When moving to the home position, home position was not detected within
specified number of pulses. (The first time: jam display, the second time: SC)
When moving from the home position, home position was still detected after
specified number of pulses. (The first time: jam display, the second time: SC)
Connecter disconnected
Overload
Home position sensor defective
Replace the Junction Gate Motor (shift/staple), reconnect the connectors.
Replace the JG HP Sensor (shift/staple), reconnect the connectors.
Replace the harness.
Replace the Main Board.
Resolve the mechanical failure for the junction gate mechanism (staple).
Error Name/Error Condition/Major Cause/Solution
Pre-stack Release Motor Error (Pressure/JG release)
When moving to the home position, home position was not detected within
specified number of pulses. (The first time: jam display, the second time: SC)
When moving from the home position, home position was still detected after
specified number of pulses. (The first time: jam display, the second time: SC)
Connecter disconnected
Overload
Home position sensor defective
Replace the Pre-stack Release Motor, reconnect the connectors.
Replace the Pre-stack Release Sensor, reconnect the connectors.
Replace the harness.