1.SC Codes
317
Error Name/Error Condition/Major Cause/Solution
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Signature thickness sensor maximum value error
When the result of the signature thickness detection (A/D value) was adjusted, the
maximum value (25mm) was smaller than the A/D value.
Signature thickness sensor defective
Connector loose, broken, defective
Slave control board defective
Master control board defective
EEPROM on the master board defective
Reconnect the connector.
Specify the signature thickness again.
Replace the signature thickness sensor.
Replace the EEPROM on the master board.
Replace the slave control board.
Replace the master control board.
Replace the sensor harness.
After the repairs, cancel the low performance mode, and then turn the power
off/on.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Signature thickness sensor value unstable error
The signature thickness reading did not change, even after the main grip unit
opened and closed.
Signature thickness sensor defective
Connector loose, broken, defective
Slave control board defective
Master control board defective
EEPROM on the master board defective
Reconnect the connector.
Specify the signature thickness again.
Replace the signature thickness sensor.
Replace the EEPROM on the master board.
Replace the slave control board.
Replace the master control board.
Replace the sensor harness.