1.SC Codes
320
Error Name/Error Condition/Major Cause/Solution
Front door solenoid defective
Front door lock release sensor defective
Connector loose, broken, defective
Master control board defective
Reconnect the connector.
Replace the front door solenoid.
Replace the front door lock release sensor.
Replace the master control board.
Replace the solenoid harness.
Replace the sensor harness.
After the repairs, cancel the low performance mode, and then turn the power
off/on.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Front door force open error
The front door open was detected open, even though it was locked.
Front door switch defective
Front door solenoid defective
Connector loose, broken, defective
Master control board defective
Reconnect the connector.
Replace the front door solenoid.
Replace the front door switch.
Replace the master control board.
Replace the solenoid harness.
Replace the switch harness.
After the repairs, cancel the low performance mode, and then turn the power
off/on.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Switchback flapper HP sensor late error
During the switchback flapper lift operation, the switchback flapper HP sensor did
not go ON, even though the switchback flapper motor operated long enough for
lifting through an arc of 50 degrees
Switchback flapper HP sensor defective
Switchback flapper motor defective
Connector loose, broken, defective