1.SC Codes
340
Error Name/Error Condition/Major Cause/Solution
Reconnect the connector.
Replace the MG lift motor.
Replace the MG press sensor (L).
Replace the slave control board.
Replace the motor harness.
Replace the sensor harness.
After the repairs, cancel the low performance mode, and then turn the power
off/on.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Main grip press sensor (L) position lag error
When raising cover in main grip from press position, MG press sensor (L) did not
go OFF, even though the MG lift motor had operated for 95 ms.
MG lift motor defective
MG press sensor (L) defective
Connector harness loose, broken, defective
Slave control board defective
Reconnect the connector.
Replace the MG lift motor.
Replace the MG press sensor (L).
Replace the slave control board.
Replace the motor harness.
Replace the sensor harness.
After the repairs, cancel the low performance mode, and then turn the power
off/on.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Signature exit sensor late error
When signature was passed from main grip to signature exit roller, signature exit
sensor did not go ON after MG lift motor moved to signature turnover position.
MG lift motor defective
Signature exit sensor defective
Signature out of position, snagged on main grip
Connector harness loose, broken, defective
Slave control board defective
Reconnect the connector.
Replace the MG lift motor.