1.SC Codes
341
Error Name/Error Condition/Major Cause/Solution
Replace the signature exit sensor.
Replace the slave control board.
Replace the motor harness.
Replace the sensor harness.
Clear the signature jam.
After the repairs, cancel the low performance mode, and then turn the power
off/on.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Main grip HP sensor (L) late error
During main grip lift, the MG HP sensor (L) did not go ON, even though the main
grip lift motor had operated for 6185 ms.
MG lift motor defective
MG HP sensor (L) defective
Connector harness loose, broken, defective
Slave control board defective
Reconnect the connector.
Replace the MG lift motor.
Replace the MG HP sensor (L).
Replace the slave control board.
Replace the motor harness.
Replace the sensor harness.
After the repairs, cancel the low performance mode, and then turn the power
off/on.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Main grip HP sensor (L) lag error
During main grip lowering, the MG HP sensor (L) did not go OFF, even though the
main grip lift motor had operated for 1455 ms.
MG lift motor defective
MG HP sensor (L) defective
Connector harness loose, broken, defective
Slave control board defective
Reconnect the connector.
Replace the MG lift motor.
Replace the MG HP sensor (L).
Replace the slave control board.