1.SC Codes
93
Error Name/Error Condition/Major Cause/Solution
2. Replace the following harness(es).
Pressure Release HP Sensor
Vertical Transport Entrance Contact Motor
3. Replace the following parts.
Pressure Release HP Sensor
Vertical Transport Entrance Contact Motor
4. Replace the Main Control Board of the LCIT.
Error Name/Error Condition/Major Cause/Solution
Vacuum Feed LCIT 1 Contact Motor: Vertical Transport Exit Contact Motor
Vacuum Feed LCIT 2 Contact Motor: Vertical Transport Exit Contact Motor
Vacuum Feed LCIT 3 Contact Motor: Vertical Transport Exit Contact Motor
When the pressure release HP sensor is detecting "H (interception)", F2
Vertical Transport Exit Contact Motor is driven a specified number of pulses
but the pressure release HP sensor is still detecting "H (interception)".
When the pressure release HP sensor is detecting "L (transmission)", F2
Vertical Transport Exit Contact Motor is driven a specified number of pulses
but the pressure release HP sensor is still detecting "L (transmission)".
F2 Vertical Transport Exit Contact Motor defective/disconnected
Pressure release HP sensor defective/disconnected
A harness to one of the parts listed above is broken.
PCB defective
Check if the SC occurs by turning the power OFF then ON. If the SC occurs again,
do the following steps. Check if the SC reoccurs by cycling the power after each
step.
To check for any abnormalities in the sensor and motor solenoid, be sure to
perform an input check and output check for them as needed in addition to a visual
check.
1. Reconnect the following connector(s).
Pressure Release HP Sensor
Vertical Transport Exit Contact Motor
2. Replace the following harness(es).
Pressure Release HP Sensor
Vertical Transport Exit Contact Motor
3. Replace the following parts.