1.SC Codes
94
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
Pressure Release HP Sensor
Vertical Transport Exit Contact Motor
4. Replace the Main Control Board of the LCIT.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC512-
00
D
Rotary gate HP error
Failed to detect "home position ON" during 2 rotations of the rotary gate after
the rotary gate stepping motor started to rotate.
Failed to detect "home position OFF" during 2 rotations of the gate after
"home position ON" was detected
("2 rotations of the gate" is equal to 877 msec.)
Rotary gate stepping motor disconnected or defective
HP sensor disconnected or defective
Malfunction due to overload
Malfunction due to an error in the motor driver
Actuator deformed, damaged, or improperly installed
Cycle the main power switch off/on.
Check or replace the corresponding motor, sensor, or harness.
Check the drive part for the load, foreign matters, etc.
Check the Actuator.
Check or replace the PCB.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC514-00
D
Registration Shift Position Error
Home position on/off was not detected within the time limit.
Shift Unit Motor connector disconnected and defective
Shift Unit HP Sensor connector disconnected and defective
Defective operation due to overload
Defective operation due to the motor driver defective
Shift Unit HP Sensor shield deformed/broken/incorrectly attached
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC515-00
D
CIS cleaning fan Error
During fan lock detection
Overload
Fan stopped by foreign object