CIP Training
Pro C9200 series
Adjustment Settings for Operators
CIP Training C7200 series
Adjustment Settings for Operators
Setting Items
Default
Value
Max.
Value
Min.
Value
Step Unit
Correction Value 0 20 -20 1 -
• After performing Perpendicularity Adjustment, execute [Color Registration] under 0201
[Execute Image Quality Adjustment] in Adjustment Settings for Operators.
0110 Switch Paper Edge Detection Sensor
Specify the level for detecting the paper edge for correcting the image position
along the feeding direction.
Setting Items Selection Default Value
Tray 1
Tray 2
2-Tray LCIT: Tray 3
2-Tray LCIT: Tray 4
2-Tray LCIT: Tray 5
2-Tray LCIT: Tray 6
2-Tray LCIT: Tray 7
2-Tray LCIT: Tray 8
Bypass Tray
Extended Option Tray
Normal
High Accuracy
Normal
• Select [High Accuracy] only when blank paper is fed. Otherwise, a paper jam may occur.