DG1000 Command System RIGOL
Programming Guide for DG1000
2-5
offset via CH1.
Explanations If the parameters you set are less than three, the sequence
would be: <frequency>, <amplitude>, <offset>.
The default units of <frequency>, <amplitude> and <offset>
are Hz, Vpp and V
DC
respectively.
Example
APPL:PULS 1000,5.0,-1.5
5.
APPLy:NOISe
Syntax APPLy:NOISe [<frequency |DEFault>[,<amplitude>[,<offset>]]]
Function Generate a Gaussian noise with specific amplitude and DC offset via
CH1.
Explanations Although the frequency parameter makes no impression on this
command, a value or DEFaultmust be specified. (noise
function has a 5MHz bandwidth)
If the parameters you set are less than three, the sequence
would be: <frequency>, <amplitude>, <offset>.
The default units of <frequency>, <amplitude> and <offset>
are Hz, Vpp and V
DC
respectively.
Example
APPL:NOIS DEF,5.0,2.0
6.
APPLy:DC
Syntax APPLy:DC [<frequency|DEFault>[,<amplitude>|DEFault>[,<
offset>]]]
Function Generate a DC signal with electrical level specified by < offset > via
CH1.
Explanations Although the frequency and amplitude parameters make no
impression on this command, a value or DEFaultmust be
specified.
If the parameters you set are less than three, the sequence
would be: <frequency>, <amplitude>, <offset>.
The default units of <frequency>, <amplitude> and <offset>
are Hz, Vpp and V
DC
respectively.
Example
APPL:DC DEF,DEF,-2.5