EasyManua.ls Logo

Rigol DG1022

Rigol DG1022
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RIGOL DG1000 Command System
Programming Guide for DG1000
2-16
Detailed information of each command:
1.
FREQuency
Syntax FREQuency {<frequency>|MINimum|MAXimum}
Function Set the frequency of output function for CH1.
Explanation <frequency> is the frequency set by user, the default unit is Hz.
MIN is the minimum frequency available for the specified function,
MAX is the maximum.
Example
FREQ MIN
2. FREQuency?
Syntax
FREQuency? [MINimum|MAXimum]
Function
Query the frequency of output function of CH1.
Return Value The query returns the frequency set in scientific notation and in
Hz, such as: 1.000000e-06.
3.
FREQuency:CH2
Syntax FREQuency:CH2 {<frequency>|MINimum|MAXimum}
Function Set the frequency of output function for CH2.
Explanation <frequency> is the frequency set by user, the default unit is Hz.
MIN is the minimum frequency available for the specified function,
MAX is the maximum.
Example
FREQ:CH2 MIN
4. FREQuency:CH2?
Syntax
FREQuency:CH2? [MINimum|MAXimum]
Function
Query the frequency of output function of CH2.
Return Value The query returns the frequency set in scientific notation and in
Hz, such as: CH2:1.000000e-06.
5.
FREQuency:STARt
Syntax
FREQuency:STARt {<frequency>|MINimum|MAXimum}
Function Set the start frequency (used in conjunction with the stop
frequency) in sweep mode.
Example
FREQ:STAR MIN
6.
FREQuency:STARt?

Other manuals for Rigol DG1022