DG1000 Command System RIGOL
Programming Guide for DG1000
Detailed information of each command:
1.
PULSe:PERiod
Syntax PULSe:PERiod {<seconds>|MINimum|MAXimum}
Function Set the period of pulse output from CH1 in seconds.
Example PULS:PER 0.01
2.
PULSe:PERiod?
Syntax
PULSe:PERiod? [MINimum|MAXimum]
Function
Query the period of pulse output from CH1.
Return Value The query returns the pulse period in scientific notation and in
seconds, such as: 1.000000e-02.
Syntax
PULSe:WIDTh {<seconds>|MINimum|MAXimum}
Function
Set the width of pulse for CH1 in seconds.
Example
PULS:WIDT 0.005
4.
PULSe:WIDTh?
Syntax PULSe:WIDTh? [MINimum|MAXimum]
Function
Query the width of pulse output from CH1.
Return Value The qurey returns the pulse width in scientific notation and in
seconds, such as: 5.000000e-03.
5.
PULSe:DCYCle
Syntax PULSe:DCYCle {<percent>|MINimum|MAXimum}
Function
Set the duty cycle of pulse for CH1.
Example
PULS:DCYC 50
Syntax
PULSe:DCYCle? [MINimum|MAXimum]
Function
Query the duty cycle of pulse output from CH1.
Return Value The qurey returns the percent of duty cycle of pulse in scientific
notation, such as: 5.000000e+01.
Syntax
PULSe:PERiod:CH2 {<seconds>|MINimum|MAXimum}