RIGOL DG1000 Command System
Programming Guide for DG1000
2-36
2.000000e+02.
7.
FM:DEViation
Syntax FM:DEViation{<frequency deviation> |MINimum|MAXimum}
Function Set the frequency deviation of FM in Hz.
Example
FM:DEV 100
8.
FM:DEViation?
Syntax
FM:DEViation? [MINimum|MAXimum]
Function
Query the frequency deviation of FM.
Return Value The query returns the frequency deviation of FM in the scientific
notation and in Hz, such as: 1.000000e+02
9. FM:STATe
Syntax
FM:STATe {OFF|ON}
Function
Disable or enable FM function.
Example
FM:STAT OFF
10.
FM:STATe?
Syntax FM:STATe?
Function Query the modulation state of FM.
Return Value The query returns OFF or ON.