CODE
Objective: Setpoint change by external voltage
Select code
KANAL l
KANAL 2
CODE
Select code
Code C100
KANAL l
KANAL 2
CODE
External voltage applica-
tion to channel 1
KANAL l
KANAL 2
CODE
I = active
0 = not active
Return
KANAL l
KANAL 2
CODE
Save and return to
main menu
If external voltage application is activated the last digital feed rate set (%) constitutes the mini-
mum feed rate for 0 volt. Set the maximum feed rate for 10 volt by the P parameter in C001.
Connect the external voltage to terminals 31, 32 and 33 in the controller.
You find the terminals behind the right-hand side panel.
Terminal 31 = +10V
Terminal 32 = E
Terminal 33 = 0V
Objective: Saving of application-specific parameters
Select code
KANAL l
KANAL 2
CODE
Select code
Code C143
Select memory location 0-
3
KANAL l
KANAL 2
CODE
Select code
Save
Return
Save and return to
main menu
US.I Selection of parameter set (0 3) in which the current parameters are to be stored.
PUSH Operate PUSH with ENTER and press a cursor button to save the current parameters to
the parameter set previously selected under US.I.
KANAL l
KANAL 2
CODE
KANAL l
KANAL 2
CODE
KANAL l
KANAL 2
CODE
4.5.8. Code C100 Setting the feed rate by external voltage input.
Attention!
Before opening the device be sure to observe the safety directives in chapter 2.
4.5.9. Code C143 Saving parameters